EasySync Ltd
Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom
Tel.: +44 (0) 141 418 0181 Fax: + 44 (0) 141 418 0110
E-Mail (Support): support@easysync.co.uk Web: http://www.easysync.co.uk
Neither the whole nor any part of the information contained in, or the product described in this manual, may be adapted or reproduced
in any material or electronic form without the prior written consent of the copyright holder. This product and its documentation are
supplied on an as-is basis and no warranty as to their suitability for any particular purpose is either made or implied. EasySync Ltd will
not accept any claim for damages howsoever arising as a result of use or failure of this product. Your statutory rights are not affected.
This product or any variant of it is not intended for use in any medical appliance, device or system in which the failure of the product
might reasonably be expected to result in personal injury. This document provides preliminary information that may be subject to
change without notice. No freedom to use patents or other intellectual property rights is implied by the publication of this document.
EasySync Ltd, Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom. Scotland Registered Number:
SC224924
Copyright © 2009-2010 EasySync Limited
The USB2-F-7x01 (USB-to CAN) is a replacement product for the EasySync CANUSB and it provides a
simple method of adapting CANbus devices to USB.
The USB2-F-7001 (USB to CAN) CAN Plus adapter, adds additional features, new advanced
commands and increase performance of the previous products. The USB2-F-7101 has all the same
features of the USB2-F-7001 and includes optical isolation between the CAN transceiver and the CAN
controller.
This programming guide describes the Windows-based API for use with high-level languages.
EasySync Ltd.
USB2-F-7x01 Programming Guide
Document Reference No.: ES_000010
Version 1.01
Issue Date: 2010-02-22
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - EasySync Ltd

EasySync Ltd Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom Tel.: +44 (0) 141 418 0181 Fax: + 44 (0) 141 41

Strany 2

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 10 2.2.5 canplus_Rea

Strany 3 - 1.1 Functional Description

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 11 2.2.6 canplus_Wri

Strany 4 - 2.1 DLL Installation

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 12 2.2.7 canplus_Sta

Strany 5 - 2.2 High-Level language API

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 13 2.2.8 canplus_Vers

Strany 6 - 2.2.2 canplus_getNextAdapter

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 14 2.2.9 canplus_Flus

Strany 7 - 2.2.3 canplus_Open

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 15 2.2.10 canplus_Re

Strany 8

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 16 2.2.11 canplus_Li

Strany 9 - 2.2.4 canplus_Close

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 17 2.2.12 canplus_Se

Strany 10 - 2.2.5 canplus_Read

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 18 2.2.13 canplus_se

Strany 11 - 2.2.6 canplus_Write

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 19 2.2.14 Error Retu

Strany 12 - 2.2.7 canplus_Status

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 2 1 Introduction ...

Strany 13 - 2.2.8 canplus_VersionInfo

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 20 3 Example Applica

Strany 14 - 2.2.9 canplus_Flush

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 21 c) API: canplus_

Strany 15 - 2.2.10 canplus_Reset

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 22 Next demo is to us

Strany 16 - 2.2.11 canplus_Listen

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 23 f) API: canpl

Strany 17 - 2.2.12 canplus_SetTimeouts

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 24 h) API: canplu

Strany 18

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 25 j) API: canpl

Strany 19 - 2.2.14 Error Return Codes

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 26 Observe the CAN

Strany 20 - 3 Example Application

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 27 4 Technical Suppo

Strany 21

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 28 5 Contact Informa

Strany 22

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 29 Appendix A – Refer

Strany 23

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 3 1 Introduction 1.1

Strany 24

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 30 Appendix B – Revis

Strany 25

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 4 2 Installation 2.1

Strany 26

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 5 2.2 High-Level lan

Strany 27 - 4 Technical Support

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 6 2.2.2 canplus_getNe

Strany 28 - 5 Contact Information

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 7 2.2.3 canplus_Open

Strany 29 - Appendix A – References

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 8 Return Codes handle

Strany 30

Document Reference No.: ES_000010 USB2-F-7x01 Programming Guide Version 1.01 Clearance No.: ES# 27 ©2009-2010 EasySync Ltd. 9 2.2.4 canplus_Close

Komentáře k této Příručce

Žádné komentáře