Document Reference No.: ES_000005
USB2-F-7x01 Full-Speed USB to 1-Port CANbus Adapter User Guide
Version 1.32
Clearance No.: ES#02
©2008 - 2011 EasySYNC Ltd. 21
4.1.6 Open CAN Channel (O)
Summary
Opens CAN channel for read/write operations. CAN channel must be initiated with selected speed
(S or s) prior to use of Open.
Definition
O<CR>
Parameters
None
Remarks
Example:
O<CR>
Open CAN channel in normal communication mode.
Once the CAN channel is open, it is necessary to execute the Echo/Synchronize (E or e)
command to flush the data buffers. Once the CAN channel is synchronized, received data is
automatically sent from the CAN network to the controlling application.
Return Codes
<CR> = OK
<BELL> = ERROR